This project involved the design and installation of a complete NFPA 13 fire sprinkler system for a 25,000 square foot office building in downtown Los Angeles. The client required a system that would integrate seamlessly with their modern open ceiling design while providing comprehensive fire protection throughout the space.
Our team worked closely with the building's architects and engineers to create a solution that met all code requirements while maintaining the aesthetic vision for the space. The installation included strategic placement of sprinkler heads, careful routing of piping, and integration with the building's other systems.
25,000 sq ft
NFPA 13
3884 Units
8 Weeks
Challenge: The client wanted to maintain an exposed ceiling design while minimizing the visual impact of the sprinkler system.
Solution: We utilized strategic pipe routing that aligned with structural elements and carefully selected black pipe with clean welds that complemented the industrial aesthetic. Sprinkler heads were positioned to provide required coverage while maintaining visual harmony.
Challenge: The open ceiling design meant all mechanical, electrical, and plumbing systems would be visible and needed to be coordinated.
Solution: We implemented BIM (Building Information Modeling) to coordinate with other trades, identifying and resolving potential conflicts before installation began. This proactive approach prevented costly rework and delays.
Challenge: Initial water flow tests indicated marginal water supply for the required sprinkler density.
Solution: We performed detailed hydraulic calculations and strategically sized piping to optimize flow characteristics. This approach eliminated the need for a fire pump, saving the client significant costs while maintaining full code compliance.
Detailed coordination with all trades to ensure proper integration of systems. Creation of shop drawings and securing necessary permits.
Installation of the main riser, fire department connection, and control valves. Pressure testing of the main riser assembly.
Installation of cross-main piping throughout the facility, ensuring proper slope and alignment with structural elements.
Installation of branch lines and sprinkler heads according to the approved design. Careful attention to spacing and coverage requirements.
Comprehensive testing of the entire system at 200 psi for 2 hours to verify integrity of all connections and components.
Coordination with LA Fire Department for final inspection. System certification and documentation provided to client.
"Premium Fire's work on our office complex was exceptional. Their team navigated the challenges of our open ceiling design with expertise, creating a system that meets all safety requirements while complementing our modern aesthetic. The project was completed on schedule and their coordination with the fire department made the inspection process seamless."
Facilities Director, Apex Properties
Commercial Office
700 San Gabriel Blvd San Gabriel, CA, 91776
April 12, 2025
5 Technicians, 1 Project Manager
NFPA 13 Compliant, LA Fire Department Approved
Our team can design and install a custom fire sprinkler system for your commercial property that meets all code requirements.
February 1, 2025
Initial consultation and site assessment. Detailed discussions of client requirements and project scope.
Initial planning meeting with client team
Engineering team developing system design
February 10-24, 2025
Development of detailed system design, hydraulic calculations, and coordination with other building systems.
February 25 - March 10, 2025
Submission of plans to LA Fire Department. Coordination with officials to secure necessary approvals.
Meeting with fire department officials
Installation team working on main risers
March 11 - April 5, 2025
Installation of main risers, cross-mains, branch lines, and sprinkler heads throughout the facility.
April 6-10, 2025
Hydrostatic testing of the system. Final inspection by LA Fire Department officials.
Final inspection with fire department officials
Final walkthrough with client team
April 12, 2025
Final walkthrough with client. Delivery of system documentation and maintenance guidelines.
Explore other commercial fire sprinkler installations we've completed
NFPA 13 system for a 15,000 sq ft retail space with specialized coverage for merchandise areas.
NFPA 13 system for a 30,000 sq ft medical office building with specialized healthcare considerations.
NFPA 13 system for a 20,000 sq ft tech company headquarters with open concept design.
Our team of experts is ready to design and install a custom fire sprinkler system for your commercial property.
Fill out this form for a no-obligation estimate for your fire sprinkler project.
CA License #584319
Serving Southern California since 1996
All systems meet NFPA standards
626-704-1823
Monday-Friday: 8am-6pm
premiumfirewills@gmail.com
We respond within 24 hours